医疗器械FDAUDI食品FDA化妆品FDAVCRP注册化妆品CPNP 加拿大化妆品通报ISO13485体系建立medical device purchasing agent, China medical device sourcing, 

    标博技术

    网站首页 > ENGLISH > Regulatory > Medical Devices

    Clinical Trials for Medical Devices

    1002 标博技术 阅读

    Companies are required to conduct the clinical trials for the higher risk medical devices in China. They are divided into clinical trial and clinical verification depending on whether the risk can be controlled. The regulations on medical device and clinical trial in China have been revised and implemented from 1st Jun 2014. It may be involve long time, great effort and resources to develop the clinical trials in China.

    Which medical device is required to conduct clinical trial in China?

    Class II and class III medical devices are required to develop clinical trial in China according to the “Regulations for the Supervision and Administration of Medical Devices”, only the devices designated by CFDA to be exempted from clinical trial are not required to conduct the clinical trial, but the clinical evaluation report should be submitted. The Catalogue of Medical Devices Exempted from Clinical Trial can be found here.

    How to confirm the clinical trial requirement?

    Companies can check the clinical trial requirement step by step as follows:
    医疗器械食品化妆品法规服务

    Which clinical trial should be approved by CFDA?

    The clinical trial of higher-risk medical devices should be approved by CFDA before conduct clinical study in China. CFDA will designate the specific medical devices and form the catalogue of class III medical devices required clinical trial approval. Any medical devices listed in the “catalogue of class III medical devices required for clinical trial approval”, companies must apply for its clinical trial approval prior to clinical study.

    Catalogue of class III medical devices required for clinical trial approval

    No.CodeScope of Product
    16821Implantable pacemaker or defibrillator
    26845Implantable blood pump
    36854Implantable drug infusion system
    46846Endovascular stent system not yet placed on the domestic market
    56846Implantable artificial organs, contacting artificial organs and orthopedics fixed or filled material, which not yet placed on the domestic market
    66846Absorbable fixation products used in the long bones of limbs
    76846Nanometer orthopedics implants
    86846Orthopedics implants produced with tailored material (3D printing)

    Powered by MetInfo 5.3.19 ©2008-2024 www.MetInfo.cn